STANDARD TOLERANCES


STANDOFFS AND SPACERS

ALUMINUM, BRASS, STEEL & STAINLESS STEEL

  • Lengths up to and including 6" (inches) the tolerance is +/-.005
  • Lengths over 6" (inches) the tolerance is +/-.010
  • Lengths up to and including 99 mm (millimeters) the tolerance is +/-.13 mm
  • Lengths from 100 mm to 150 mm the tolerance is +/-.20 mm
  • Lengths over 150 mm the tolerance is +/-.25 mm
Tolerances for the outside diameters are +/-.005.

PHENOLIC, NYLON, TEFLON AND DELRIN

  • For all lengths the tolerance is +/-.010
  • For the outside diameter the tolerance is +/-.010

Return to Engineering Data Page