American Standard Sizes: All Dimensions are in Inches

SHANK DIA. “B”.198.228.280.366.414.479
“X” DIA..188.218.270.356
.404
.469

Panel Screw Retainers – Non Press Fit Styles Only

American Standard Sizes: All Dimensions are in Inches:

SHANK DIA. “B”.188.218.250.270.356.404.406.433
“X” DIA..191.221.257.272.359.407.407.437
“Y” DIA..252.282.318.333.420.468.468.498

Rule of thumb for “Y” countersink: Y = X + .045 min. or 0.78 max

Knurled Shank Retainers – Press Fit Only

Metric Sizes: All Dimensions are in Millimeters

SHANK DIA. “B”55.87.19.3
“X” DIA.4.755.546.869.04

Panel Screw Retainers – Non Press Fit Styles Only

Metric Sizes: All Dimensions are in Millimeters

SHANK DIA. “B”6.311
“X” DIA.6.511.2
“Y” DIA.812.6

Rule of thumb for “Y” countersink: Y = X + 1.14 min. or 1.98 max